<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-06 01-34-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 67 kHz 13849 9,7047
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,4 dBr 5,06 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 67 kHz MIN: 10 kHz % above 76 kHz: 9,7047 Acquired: 2025/03/06 1.33.04 Total samples: 13849 Equivalent time: 0:11:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 5,6 dBr MIN: 4,4 dBr AVE: 5,06 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2025/03/06 1.33.04) 01.20 01.22 01.24 01.26 01.28 01.30 01.32 0 2 4 6 Pm [dBr]